DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-783EXP-INTF (Expansion Interface Circuit Pack)
9
Figure 9-38. Direct Connect Configuration with Duplicated PNC
In a duplicated PNC there is an A-side PNC and a B-side PNC. All EIs in this
diagram are labeled with an A or a B to designate which PNC they are a part of.
Note that the PNC designation (A or B) does not relate directly to carrier location.
Again, only one of the EIs in an EPN can function as an archangel (TDM Bus
Master). The EI that is on the active PNC and that is connected to the PPN is the
only one that can function in this mode. In normal operation, its yellow LED
should be blinking at a rate of 2 seconds on and 200 ms. off.
Figure 9-39
shows the location of EIs in a typical center stage switch
configuration with simplex PNC.