DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-79ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
Aux Data 40977 indicates that no terminal equipment was connected
when ringing was attempted. Run the short test via the
test port
UUCSSpp
command, and follow the procedure for the results of Test #48.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate errors (if any).
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11-minutes. To clear the error, reinsert or
replace the circuit pack.
d. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing is disturbing the customer or the terminal
equipment, it should be disabled via the
change station
extension
command. However, on some releases of the software, this will disable
Tests #6, 47, and 35 as well as Test #48.
e. Test #47 may cause a false alarm when the port is connected to
off-premises equipment, some non-voice terminal equipment, and some
loop equipment. If this causes a false alarm, then disable the test by
changing the Tests field of the
change station
command to ‘‘no.’’
f. Refer to ‘‘XXX-BD (Common Port Circuit Pack)’’ Maintenance
documentation.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Battery Feed Test
, for example, you may also clear errors generated from other
tests in the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Battery Feed Test (#35) X X ND
Station Present Test (#48) X X ND
NPE Crosstalk Test (#6) X ND
Loop Around and Conference Test (#47) X ND
Station Status and Translation Audits and
Updates Test (#36)
XXND