A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-714DUP-CHL (Duplication Interface)
9
Duplication Channel Test (#874)
This test verifies the correct transmission of a message sent from the active SPE
to the standby SPE via the Duplication Interface circuit pack mailbox
1420 ABORT The state-of-health of the active SPE is partially functional.
1. Use the display alarms command selecting the SPE category to
determine which alarms have caused the active SPE to have a lower
state-of-health. Problems causing MAJOR alarms for MEM-BD, PKT-INT,
SYSAM, H-ADAPTR, and SW-CTL should be repaired first.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure described in Chapter 5
to power down and power up the standby SPE, but don’t replace any
circuit packs. Try this test again.
2000 FAIL This test did not run because communication with the standby timed out while
waiting for a reply to a maintenance message instructing it to lower it’s
state-of-health.
1. Replace Duplication Interface components starting with the standby
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of this section.
2334 ABORT The hardware mailbox in the standby Duplication Interface circuit pack is not
ready to receive messages.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure described in Chapter 5
to power down and power up the standby SPE, but do not replace any
circuit packs.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The standby state-of-health was lowered but no interrupt was received after the
test had instructed the standby SPE to lower its state of health.
1. Replace Duplication Interface components starting with the standby
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of this DUP-CHL section.
PASS The test successfully received the lowered state-of-health interrupt from the
standby Duplication Interface circuit pack.
Table 9-276. TEST #873 State-Of-Health Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page