DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-753E-DIG-STA (Emulated Digital Line)
9
Station Lamp Updates Test (#16)
This test lights all lamps on the terminal as specified. The lamp updates will run
only if the station is in-service. The status of the station is checked and the lamp
updates are blocked from taking place if the station is not in the in-service state.
This test does not affect the status of the Message Waiting lamp.
PASS The test passed, and all channels are transmitting properly.
1. To ensure that this is not an intermittent problem, repeat this test up to
10 times.
2. If noisy connections for voice or corrupted data for data transfer
persist, examine the station, connections, and wiring.
Table 9-291. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code
Tes t
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 ABORT System technician may have busied out the port.
1. Look for Error Type 18 (port busied out) for this port. If this error type
is present, then release the port (release station
extension
) and run
the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
3 ABORT Station may be in ready-for-service or out-of-service state.
1. Use the status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-290. TEST #13 Voice and Control Channel
Local Loop Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page