DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1106M/T-BD (Maintenance/Test Circuit Pack)
9
c. A port processor on the circuit pack failed to initialize. Reset the circuit
pack via
busyout board UUCSS
,
reset board UUCSS
, and
release
board UUCSS
. if the problem does not go away, replace the circuit pack.
d. A Control Channel Protocol Error has occurred. This may be due to an
on-board hardware failure detected by the circuit pack. Reset the circuit
pack by executing
busyout board UUCSS
and
reset board UUCSS
commands. If there is a problem, it will be detected during initialization
and will cause the circuit pack to lock up and appear insane to the
system.
e. An extra TN771D circuit pack has been inserted into the port network.
f. An on-board hardware failure has been detected by the circuit pack.
Reset the circuit pack via the
busyout board UUCSS
,
reset board
UUCSS
, and
release board UUCSS
commands. If SAKI Sanity Test (#53)
passes, the circuitry is healthy. If SAKI Sanity Test (#53) fails, replace the
circuit pack.
g. This error is reported by the circuit pack when it detects a program logic
error. While no action is required, this error may lead to errors of other
types being reported against this circuit pack.
h. This error is reported by the circuit pack when it cannot update NPE
memory and read it back. This error type can be ignored, but may lead to
errors of other types being reported against this circuit pack.
i. Excessive number of messages have been received from the
Maintenance/Test circuit pack. This may be due to a hardware problem on
the circuit pack. The switch will take the board out of service and
periodically put it back into service to see if the problem has disappeared.
If the problem persists, replace the circuit pack.
j. This error is not service affecting. No action is required. This error is
reported by the circuit pack when it receives a bad control channel
message from the switch.
k. Error type 3999 indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
error type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If error type 1538 is not present, then
the circuit pack has not been taken out-of-service, but it has generated
50% of the messages necessary to be considered hyperactive. This may
be completely normal during heavy traffic periods. However, if this error
type is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the