Maintenance Object Repair Procedures
9-759EMG-XFER (Emergency Transfer)
9
Table 9-293. TEST #124 Emergency Transfer Query Test
Error
Code
Tes t
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to ABORT with Error Code 2000, check for system
powering problems with the A carrier (PPN or EPN). Resolve all AC-POWER
and CARR-POW alarms in a multi-carrier cabinet system or DC-POWER
alarms in a single-carrier cabinet system. Then, repeat the test.
3. If the test continues to ABORT with a 2000 Error Code, resolve all SYSAM
errors in a PPN, or MAINT (EPN Maintenance circuit pack) errors in an EPN.
Then, repeat the test.
2029
2319
2320
2500
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
17
18
20
33
65
289
FAIL Emergency Transfer is manually turned OFF (Emergency Transfer switch off).
1. Place the switch (or switches in a PPN with duplicated SPE) in the AUTO
position.
34
290
FAIL Emergency Transfer is manually turned ON (Emergency Transfer switch on).
1. Place the switch (or switches in a PPN with duplicated SPE) in the AUTO
position.
PASS System software has control of Emergency Transfer within this cabinet. If
Emergency Transfer is currently invoked (the emergency transfer LED is on),
the cause could be a major alarm.
1. The following list shows the error types that can cause Emergency Transfer.
If any of these errors appear in the log, then refer to the appropriate section
and resolve those problems first.
TAPE
SW-CTL
TONE-BD, Error Type 3585 Aux Data 121; Error Type 2305, Aux Data 40800
2. If none of the above errors appear in the log, then check the Emergency
Transfer hardware.
3. On an EPN, if Emergency Transfer is invoked while call processing is
permitted, verify that the current limiter card (982LS) is in the correct slot on
the backplane. If the current limiter card is not in the correct slot, move it to
the correct location and rerun Test #124.
Continued on next page