DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-469DC-POWER (Single Carrier Cabinet Environment)
9
Single Carrier Cabinet Power Query Test (#79)
This test queries the EPN Maintenance circuit pack (in an EPN) about the status
of the power in a single carrier cabinet system. This test can only detect power
problems in carriers in the Port Network for which the Carrier Port Power Supply
is physically present.
Table 9-195. TEST #79 Single Carrier Cabinet Power Query Test
Error
Code
Te s t
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to ABORT with a 2000 error code, check for and
resolve all MAINT (EPN Maintenance circuit pack) errors. Then, repeat
the test.
3. If the test continues to ABORT with a 2000 error code, then escalate the
problem.
2029
2319
2320
2500
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page