Maintenance Object Repair Procedures
9-1769TIE-TRK (Analog Tie Trunk)
9
1018 ABORT Test disabled via administration.
1. Verify that the ‘‘Maintenance Tests?’’ field on the Trunk Group Form is set to
"n". To enable the test, issue the change trunk-group x command where
‘‘x’’ equals the number of the trunk group to be tested. Then change the
entry in the ‘‘Maintenance Tests?’’ field on the form to ‘‘y.’’
1040 ABORT This test is not performed for trunk ports administered as access endpoints.
1. Verify this port is an access endpoint by using the display port command.
2. If the port has been administered as an access endpoint, then this test
should abort.
2100 ABORT Could not allocate the necessary system resources to run the test. This could be
due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
3 FAIL No dial tone detected from the other end. (TN439 circuit packs only.)
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to fail, check the far-end PBX to ensure a translation
match at both ends.
3. Check the facility.
2000 FAIL Seizure message is not received back within 10 seconds.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, check the far-end PBX to ensure a translation
match at both ends.
3. Check the facility.
PASS The Tie Trunk Seizure Test passes. This port is functioning properly.
1. If users are reporting troubles, examine loop connections to the port, wiring,
and stations.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the board,
if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 9-663. TEST #73,#747 Tie Trunk Seizure Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page