DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1850UDS1-BD (UDS1 Interface Circuit Pack)
9
1301 FAIL The 120A1 CSU Module is physically connected to the TN464F board on the
back of the port carrier but the
Near-End CSU Type
field on the
add ds1
form
has not been administered as
integrated
.
1. If the 120A1 CSU Module is to be used, use the
change ds1
command to
change the
Near-End CSU Type
field to
integrated
. Otherwise, physically
remove the 120A1 CSU Module from the back of the port carrier.
2. Run the test again.
1302 FAIL Attempting to use the 120A1 CSU Module with a TN464F circuit pack that is
configured for 32-channel (2.048 Mbps) operation. The CSU Module only works
with a DS1 board configured for 24-channel (1.544 Mbps) operation in the
United States of America.
1. If the 120A1 CSU Module is to be used, physically remove the TN464F
circuit pack and reconfigure for 24-channel (1.544 Mbps) operation.
2. Reinsert the circuit pack and run the test again.
1303 FAIL The DS1 circuit pack Suffix is incorrect for CSU Module administration. The
Near-End CSU Type
field on the
add ds1
form has been administered as
integrated
but the DS1 circuit pack is not a TN464F or later suffix UDS1 board.
1. If the CSU Module is to be used, and the
Near-End CSU
Type field is set to
integrate to allow for CSU Module administration, remove the circuit pack
and replace it with a TN464F or later suffix board. Otherwise use the
change ds1
command to change the
Near-End CSU Type
field to
other
.
1310 FAIL The DS1 Board Loopback (BLB) demand test (#1209) failed.
1. Repeat the test using the
test ds1-loop UUCSS ds1/csu-loopback-tests
command.
2. If the BLB test continues to fail, then replace the TN464F circuit pack.
3. Run this test again.