A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-173ping node-name
8
ping node-name
This command performs a ping test exactly like the
ping ip-address
command,
except you enter an administered node-name (
display node-names
).
Output
The command output looks the same as Screen 8-4.
recycle carrier
recycle carrier UUC
The recycle carrier command turns power off, then back on, on a specific carrier.
When a power unit is replaced in a carrier, this command must be entered to
restart the power on that carrier. The following carriers cannot be recycled:
PPN Control Carrier (active or standby)
Switch Node Carrier
EPN Control Carrier
Any carrier holding an active Tone-Clock or an active Expansion Interface
circuit pack
!
CAUTION:
When a port carrier is recycled, all ports and adjuncts supported by circuit
packs on that carrier undergo a service outage.
!
CAUTION:
Never recycle power to a carrier containing DEFINITY AUDIX
TN566/TN2169 circuit packs without first shutting down the AUDIX system.
Doing so can damage AUDIX software. Follow instructions on the
TN566/TN2169 faceplate (these also appear under ADXDP-PT in
Chapter
9, ‘‘ABRI-PORT (ASAI ISDN-BRI Port)’’
). On G3r V1 systems, the
TN566/TN2169 may appear as a TN746 with a vintage greater than 50.
For more information see Common Input Parameters and Common Output Fields
at the beginning of this chapter.
Action/ Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
ping node-name
board
repeat
Example:
ping node-name
nname
init
inads
craft
none none