DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Architecture
1-8How to use the Maintenance book
1
8. Note the Error Type (
Err Type
field) value (1547) and the
Aux Data
value if present.
9. Find the DID-TRK MO in the Maintenance Object chapter of the
appropriate maintenance book.
10. In the first table look up the initial command to run in the MAJOR row of the
table (Step 4 indicated that a DID trunk in slot 10, carrier C has a MAJOR
alarm).
11. Type
test port 01C1008 long
and press
Enter.
“01C1008” is the address of the alarmed port (see
Screen 1-2
and
Screen
1-3)
12. While the port test is running, look up the Error Type (1537 from
Screen
1-3) in the DID Trunk Error Log Entries table (example below).
13. Since the Test to Clear Value (
test port 01C1008 sh r 1) is very similar to the
initial test you ran in Step 11, wait for the results of the port test.
14. When the port test finishes, the following display appears (Screen 1-4):
MO Name (in
Alarm Log) Alarm Level Initial Command to Run
1
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs),
C
is the carrier designation (A, B,
C, D, or E),
SS
is the number of the slot in which the circuit pack resides (01 to 21), and
pp
is the
two digit port number (01, 02, ...).
Full Name of MO
DID-TRK MAJOR
2
2. A MAJOR alarm on a truk indicates that alarms on these trunks are downgraded by the set options
command and that at least 75% of the trunks in this trunk group are alarmed.
test port UUCSSpp long DID Trunk
DID-TRK MINOR test port UUCSSpp long DID Trunk
DID-TRK WARNING test port UUCSSpp DID Trunk
Table 1-2. DID Trunk Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1537 Port Diagnostic
(#35)
MAJ/MIN/
WRN
OFF test port UUCSSpp sh r 1
3840 (k) 40965 None
Continued on next page