![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg64d.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-929INADS (INADS Link)
9
is also logged against INADS if the call to INADS finally succeeds. The INADS
software (release 3.2 or later) recognizes this special ‘‘test inads’’ type of alarm
and will automatically open and then close a trouble ticket which indicates that
the reason for the trouble ticket is a
test inads-link
command. The trouble ticket
alarm will contain a ‘‘TESTING INADS LINK’’ description field.
After entering the command, it may take as long a 9 minutes for the switch to
place the call and for INADS to respond. The Error Log should be examined
using the category
inads
10 minutes after successfully entering the command to
determine if the call was successful. Table 9-357
explains the error codes.
Table 9-357. INADS Link Test Error Log Entries
Error
Code
Tes t
Result Description/ Recommendation
1 0 The call was successfully placed to INADS. No trouble found.
2 0 Informative error indicating that alarm origination was disabled at the time of
the test. The test will still run even if alarm origination is disabled.
1. If Alarm Origination is desired, then enable this feature via the
Maintenance-Related System Parameters Form.
2. Repeat the test.
3 0 The INADS connection is currently in use.
1. Wait 10 minutes and retry this command.
4 0 INADS did not answer the alarm origination call.
1. Verify INADS is up and running.
2. Verify that the INADS phone number and switch product id are correct via
the Maintenance-Related System Parameters Form.
3. Enable alarm origination via the Maintenance-Related System Parameters
Form and test the SYSAM (System Access Maintenance) by issuing the
test maintenance a|b command. If SYSAM Tests #916 and #917 do not
pass, then refer to SYSAM (System Access Maintenance) Maintenance
documentation.
4. Retry the command.
5 0 No INADS phone number administered.
1. Administer the INADS phone number via the Maintenance-Related System
Parameters Form.
2. Retry the command.
Continued on next page