9-716DUP-CHL (Duplication Interface)
9
Remote SPE Error Interrupt Test (#875)
This test is used to check for the correct operation of the Remote SPE Error
interrupt
2334 FAIL The hardware mailbox in the standby Duplication Interface circuit pack is not
ready to receive messages.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this failure continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure described in Chapter 5
to power down and power up the standby SPE, but do not replace any
circuit packs.
3. Replace Duplication Interface components starting with the standby
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of this section.
PASS The standby software returned the test message sent from the active SPE to the
standby SPE via the Duplication Interface circuit pack mailbox.