Additional Maintenance Procedures
6-45Automatic Transmission Measurement System (ATMS)
6
processing, the test aborts. When the trunk is already being tested by
maintenance software, the test is queued and run when the maintenance activity
finishes.
Measurement data gathered by analog testcalls can be retrieved with the
list
testcalls
command which is described below. Which measurements are made
and recorded depends on which type of test is specified and the capabilities of
the far-end TTL.
Screen 6-1
shows a typical result for
test analog-testcall trunk 60
Screen 6-1. Test Results for test analog-testcall trunk 60
Output Fields
Port
The physical location of the port supporting the trunk
being tested. The format is UUCSSpp where UU is the
cabinet number, C is the carrier letter, SS is the circuit
pack slot, and pp is the port circuit number.
Maintenance
Name
The name of the maintenance object tested, TIE-TRK
or CO-TRK.
Alt. Name
The trunk group number and member number of the
trunk being tested.
Test Number ATMS tests are numbered 844 through 848.
Result If the test call successfully completes, and all trunks
test within administered thresholds for marginal and
unacceptable performance, then a PASS result is
returned. If measurements fall outside the thresholds,
the test fails. The trunks group can be administered to
log errors and alarms, and to busy out the failed trunk.
If the test call cannot be completed, an ABORT is
returned.
test analog-testcall trunk 60 SPE B
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02B1901 TIE-TRK 060/001 845 PASS
02B1902 TIE-TRK 060/002 845 PASS
02B1903 TIE-TRK 060/003 845 PASS
02B1904 TIE-TRK 060/004 845 ABORT 1004
02B1905 TIE-TRK 060/005 845 PASS
02B1906 TIE-TRK 060/006 845 ABORT 1004