9-1265PKT-INT (Packet Interface Circuit Pack)
9
2 FAIL The Private Level 2 looparound test failed. The circuit pack will enter a fatal
fault state when this occurs and the Packet Interface Maintenance software
should put the circuit in a out-of-service state. Therefore by the time further
action is taken, it is expected that the test will abort with ABORT code 1137
and a demand reset should be used to test the circuit pack.
1. Reset the circuit pack using the reset packet-interace CS command.
Refer to the repair procedures for the Packet Interface Reset Test (#889)
for further action.
2. If the test continues to fail, replace the Packet Interface circuit pack.
3 FAIL The Private Link Level 3 looparound test failed. The circuit pack may still be
operational.
1. Retry the command.
2. If the test continues to fail with the same error code:
a. If the system is not equipped with the High Reliability or Critical
Reliability Configuration replace the Packet Interface circuit pack.
b. If the system is equipped with the High Reliability or Critical Reliability
Configuration and if the Packet Interface circuit pack is on the standby
SPE, replace the circuit pack on the standby SPE.
c. If the system is equipped with the High Reliability or Critical Reliability
Configuration and if the Packet Interface circuit pack is on the active
SPE,
3. Perform a planned SPE interchange by entering the command reset
system interchange. Use the status spe command to determine when
refresh is complete (between 2 to 10 minutes, depending on system size)
and retry the test command.
4. If the test of the circuit pack on the standby SPE continues to fail, replace
that circuit pack.
PASS All the private looparound tests passed. The circuit pack is functioning
properly. If the system is still unable to place calls on cabinets other than the
SPE cabinet, then:
1. Display the error log using the command display errors and check for
errors on the Packet Bus and Maintenance/Test circuit pack. Clear those
errors first.
2. Check all other circuit packs connected to the Packet Bus in the same
cabinet. Packet Bus failures are likely to be caused by a faulty circuit pack
connected to the backplane or bent pins on the back plane. Refer to the
PKT-BUS maintenance documentation for repair procedures.