![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg78.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Initialization and Recovery
4-2Multiple Offer Categories
4
described under PNC-DUP in Chapter 9, and under
reset pnc interchange
in
Chapter 8, ‘‘Maintenance Commands’’
.
Multiple Offer Categories
When the system is initially powered up, or when it experiences a catastrophic
fault that interrupts its basic functions, the system either initializes or reboots.
Initialization
Upon initialization, no forms (not even Customer Options) are available until the
Offer Category is set. (The remote INADS channel is available.) To set the
customer options, do the following:
1. Enter
change system-parameters offer-options
(init and inads logins
only) and the following form displays:
Field descriptions
2. After these two fields are filled and you press Enter, the system displays:
WARNING: Activating Offer Category may set unchangeable
limits.
This is to let you know that the Offer Category along with the model
determine the system capacities (limits) and allowable hardware.
3. Press the
Submit key to submit the form.
Offer category
Type either
A
or
B
.
Activate offer?
Type
y
if the entry for
Offer category
is correct and press Tab.
Type
n
if there is an error in the
Offer category
field and press
Tab . Re-enter the correct Offer Category.
change system-parameters offer-options
OFFER OPTIONS FORM
Offer Category: _
Activate Offer? _
WARNING: Need to save translations and reboot to make the change permanent.