![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg2b8.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-12ADM-CONN (Administered Connection)
9
For all ADM-CONN errors:
All of the above errors have no specific test associated with them and, except for
errors 17 and 127, are valid only for administered connections established over
ISDN-PRI facilities. Error 127 is valid for administered connections established
over non-ISDN facilities or between two endpoints on the same switch.
Notes:
a. These errors are typically associated with administration problems and are
not expected to be of a temporary nature. The administered connection is
not retried and the failure is alarmed immediately. The alarm threshold
specified by the customer is ignored.
b. The address of the destination endpoint is: an unassigned number (1),
has an invalid number format (28), or is restricted from terminating calls
due to Class of Restriction (‘‘Access Denied’’). Verify that the destination
address is correct and that the destination endpoint is administered. The
destination endpoint is not administered on the switch where this error is
logged.
c. A request has been made to use a transit network or common carrier that
cannot be accessed. Check the routing pattern used by this administered
connection and verify that the inter-exchange carrier specified is correct.
16 (a) Any None Any OFF None
17 (e) Any None Any OFF None
18, or 102 (f) Any None Any OFF None
22 (a,g) Any None Any OFF None
34,42,44, or 58 (h) Any None Any OFF None
38, or 41 (i) Any None Any OFF None
43, or 81 Any None Any OFF None
50 (a) Any None Any OFF None
52 (a) Any None Any OFF None
54 Any None Any OFF None
65,66, or 69 (a) Any None Any OFF None
82 Any None Any OFF None
88 (a) Any None Any OFF None
91,95,96,97,98,99,1
00, or 111
Any None Any OFF None
Table 9-5. Administered Connection Error Log Entries — Continued
Error Type
Aux
Data
Associated
Te s t
Alarm
Level
On/Off
Board
Test to Clear
Value
Continued on next page