A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-746E-DIG-STA (Emulated Digital Line)
9
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence
and only one test path in the test sequence. Once the test sequence is started,
all tests in the test sequence are executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administered as a digital
station. These include stations with an emulated digital voice terminal and
stations with an emulated digital voice terminal and a linked data module.
Stand-alone data modules and data adaptors in stand-alone mode are not
supported by the TN800 circuit pack. Circuit pack maintenance is covered by
E-DIG-BD.
Hardware Error Log Entries and
Test to Clear Values
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run
1
(a) (b)
1. Where UU is the universal cabinet number (1 for PPN and 2-44 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ...); and pp is the two digit port
number (01, 02, 03, ...).
Full Name of MO
E-DIG-STA MINOR test port UUCSSpp l Emulated Digital St.
E-DIG-STA WARNING test port UUCSSpp sh Emulated Digital St.
Table 9-288. Digital Line Error Log Entries - E-DIG-STA
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port UUCSSpp sh r 1
18 (a) 0 busyout port UUCSSpp WNG OFF rel port UUCSSpp
130 (b) None WNG ON test port UUCSSpp sh
257 (c) 40971 None
1537 (d) 40968 None WNG OFF
1793 (e) Voice and Control Local
Loop Test (#13)
MIN/
WNG
2
ON test port UUCSSpp l r 3
2049 (f) NPE Crosstalk Test (#9) MIN/
WNG
2
ON test port UUCSSpp l r 3
Continued on next page