DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-430CO-TRK (Analog CO Trunk)
9
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors.
c. This error type indicates that the circuit pack has been removed or has
been insane for at least 11-minutes. To clear the error, reinsert or replace
the circuit pack.
d. Aux data 57345
Single polarity ringing current
Aux data 57376
No loop current on incoming call
Aux data 57408
No tip ground detected on outgoing call
1793 Looparound and
Conference Test
(#33
MAJ/MIN/
WRN
2
ON test port
UUCSSpp
l r 3
2049 NPE Cross Talk Test
(#6)
MAJ/MIN/
WRN
2
ON test port
UUCSSpp
l r 3
2561 (d) 57345 None
2817 (a) 57360 None
2817 (a) 57393 None
2817 (d) 57484 Dial Tone Test(#0) MAJ/MIN/
WRN
OFF test port
UUCSSpp
l r 1
3073 (d) 57376 None
3329 (d) 57408 None
3329 (d) 57484 Dial Tone Test(#0) MAJ/MIN/
WRN
OFF test port
UUCSSpp
l r 1
3585 (d) 57424 None
3840 (f) 8000 Transmission Tests
(ATMS)(#844-848)
OFF test analog-testcall
3841 (f) Transmission Tests
(ATMS)(#844-848)
MINOR OFF test analog-testcall
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Table 9-179. CO Trunk Error Log Entries — Continued
Error
Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page