![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg432.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-390CLAN-BD (Control LAN Circuit Pack)
9
Notes:
a.
Error Type 1
: Circuit pack stopped functioning or is not physically
present.
1. Verify that the circuit pack is present.
2. If circuit pack is present, reset the circuit pack (
reset board
UUCSS
).
3. If the error persists, replace the circuit pack.
b.
Error Type 18
: The CLAN circuit pack busied out.
c.
Error Type 217
: applies to 3 circuit packs:
d. Error Type 257: Transient communication problem between switch and
circuit pack; does not affect service and can be ignored.
1. Ignore this error.
Repetitive failures of the Control Channel Loop Test indicate circuit pack
hardware failure.
e. Error Type 513: Circuit pack detected and reported hardware failure.
1. Reset the circuit pack (reset board UUCSS).
3842 (s)
3844 (t) Any
3999 (p) Any None
Circuit
pack Description
Maintenance/Test More than one Maintenance/Test circuit pack in the port
network
Tone Detector
Call Classifier
More than 10 circuit packs in the system.
1. Remove the circuit pack(s) against which the error is
logged.
Continued on next page
Table 9-162. CLAN-BD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page