9-1240PKT-BUS (Packet Bus)
9
optionally install a Maintenance/Test circuit pack in order to make use of its
analog trunk and digital line test capabilities, and to enhance the system’s
analog trunk and digital line test capabilities, system’s ability to quickly
recognize a packet bus failure.
Table 9-495. Test #572 Maintenance/Test Circuit Pack
Query Test
Error
Code
Tes t
Result Description/ Recommendation
1006 ABORT The packet bus port of the Maintenance/Test circuit pack is out of service.
1. Determine if the port is busied out. If so, release it with the release port
UUCSS04 command. Then retry the test command.
2. If there are alarms active against the packet bus port (MT-PKT), refer to
M/T-PKT Maintenance documentation to resolve them. Then retry the test
command.
1142 ABORT No Maintenance/Test circuit pack packet bus port is in service in this
port-network.
1. If this port-network is required by configuration guidelines to have a
Maintenance/Test circuit pack (i.e., it is either a PPN or else an EPN in a
system having both SPE and PNC duplication) either
a. the Maintenance/Test circuit pack for this port-network has failed, and
should be replaced,
b. the Maintenance/Test circuit pack has been busied out, and should be
released, or
c. there is no Maintenance/Test circuit pack in this port-network, and one
must be installed.
2. In an EPN of a system without both SPE and PNC duplication, the
Maintenance/Test packet bus Port is not required and may not be present.
If it is present, and is busied out, or has failed, release or replace the circuit
pack. If there is no Maintenance/Test circuit pack, ignore the results of this
test for this port-network.
2000 ABORT The test timed-out while waiting for an uplink CCMS response from the
Maintenance/Test packet bus port.
1. Re-enter the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, check for problems with the Maintenance/Test
packet bus port (look for M/T-PKT in the Error and Alarm Logs).
2059 ABORT The Maintenance/Test packet bus port has reported a hardware failure.
1. Refer to M/T-PKT Maintenance documentation to correct the problem.
2. Re-enter the test command.