A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-120ANN-PT (Announcement Port)
9
2. Performing a
test board long
when the circuit pack is in this state will
yield the following abort codes:
Ports 1 AND 9 abort Test 206 with code 1024.
Ports 1 AND 9 abort Test 205 with code 2000.
Board level Tests 209 and 210 abort with code 1024.
3. The
save/restore announcements
command will time out with:
Error encountered, can’t complete request
The Announcement circuit pack lock-up can be cleared remotely by performing
a soft reset to the circuit pack:
busy-out board UUCSS
(this command drops all calls in progress on the
Announcement circuit pack).
Reset circuit pack using the
reset board UUCSS
command.
Release board using the
release board UUCSS
command.