A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1251PKT-INT (Packet Interface Circuit Pack)
9
For the case where not all links are in the ‘‘Failed Links’’ category, examine
the alarm log and error log for failures of the following circuit pack types
and follow the repair procedures for those circuit packs before
considering replacing the associated Packet Interface circuit pack:
Expansion Interface circuit pack (EXP-INTF)
Switch Node Interface circuit pack (SNI-BD)
Switch Node Clock circuit pack (SNC-BD)
Packet Data Line circuit packs and ports (PDATA-BD, PDATA-PT)
ISDN-BRI Line circuit packs, ports, and stations (BRI-BD,
BRI-PORT, BRI-SET)
Packet Gateway circuit packs and ports (PGATE-BD, PGATE-PT)
Universal DS1 circuit packs and ports (UDS1-BD, TIE-DS1)
Error Log Entries and Test to Clear Values
Table 9-497. Packet Interface Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any ON test packet-interface CS l r
2
1 (a) Any None MAJOR
2
ON reset packet-interface CS
3
10 (b) 0 None
23 (c) 0 None MAJOR
2
OFF
23 (d) 0 None MINOR OFF
50 (e) 0 None
100 (f) 0 None
150 (g) 0 None MAJOR ON test packet-interface CN l c
200 (h) 0 None MAJOR
2
OFF
217 (j) 0 None WARNING OFF
257 (i) Any None MAJOR
2
ON reset packet-interface CS
3
267 (j) 0 None WARNING OFF
513 (k) Any None MAJOR
2
ON reset packet-interface CS
3
769 (l) Any Maintenance
Looparound Test
(#886)
MAJOR
2
ON test packet-interface CS s r
2
Continued on next page