DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1040MET-LINE (MET Line)
9
Error Log Entries and Test to Clear Values
Notes:
a. The data link between the port and the terminal is not operational, i.e., the
port circuitry has detected an off-board problem. Verify that the MET set is
connected and that the Electronic Power Feed (EPF) test passes. If data
transmission problems are experienced, check for defective wiring or a
defective voice terminal, or move terminal electrically closer to the switch
(i.e., reduce the length of the wiring between the terminal and the switch).
If the problem persists, replace the circuit pack. Once the problem is
resolved, the system retires the alarm after a predetermined time delay.
Table 9-411. MET Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40987 None
18 (b) 0 busyout port
UUCSSpp
WARNING OFF release port UUCSSpp
130 (c) None WARNING ON test port UUCSSpp sh
257 (d) 40988 None MIN/WRN
2
2. Major or Minor alarms MO may be downgraded to Warning alarms based on the values used in the set
options command.
OFF
513 (e) 40965 Hybrid Line Station
Audits Test (#61)
WARNING OFF test port UUCSSpp sh r 4
769 Port Diagnostic Test
(#35)
MIN/WRN
2
ON test port UUCSSpp l r 3
1025 Hybrid & Conf.
Circuits Test (#57)
MIN/WRN
2
ON test port UUCSSpp l r 3
1537 (f) 40968 None MIN/WRN
2
OFF
1793 TDM NPE Crosstalk
Test (#6
MIN/WRN
2
ON test port UUCSSpp l r 3
2049 (g) 32770
2049 (h) 40967
3840 (i) 40989