DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-355test packet-interface
8
test packet-interface
test packet-interface [CSS] [short | long] [repeat # |clear] [schedule]
This command performs hardware diagnostic tests on any or all of the packet
interface circuit packs in a specified carrier. Tests performed include local
memory checksum tests, loop-around tests, and checks of failure counters.
The Maintenance Loop-Around Test (#886) is included in the test sequences of
active
packet-interface circuit packs only. The Active-Standby Peer Link Test
(#888) is included in the test sequences of the
standby
packet-interface circuit
packs only.
If the packet-interface circuit pack is in the “out-of-service” or “uninstalled”
states, no demand tests as well as scheduled, periodic and error tests will run.
See also
reset packet-interface
and
status packet-interface
.
Parameters
CSS
The cabinet is always 1 and need not be entered. The carrier,
a
or
b
, must be
entered only for duplicated SPEs. Slot number ranges from 1 to 3,
corresponding to the dedicated PKT-INTFC slots on the control carrier. If
omitted, all Packet Interface circuit packs on the specified carrier are tested.