DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-860FIBER-LK (Fiber Link)
9
Configuration Audit (#759)
This test is non-destructive.
This test is run via the
test board short
or
test board long
command for SNI
circuit packs or via
test fiber-link
for fiber links with SNI endpoint(s).
This test queries the SNI for SNC s in the same switch node carrier, SNI peers,
DS1 CONV s, and EI or SNI neighbors that the SNI can communicate with and
compares this data to the administered data.
Failures of this test cause entries in the error and alarm logs against Switch Node
Configuration (SN-CONF) with the board location of the SNI.
This test is unable to detect the case where an SNI is connected to the same type
of board (EI or SNI) as administered but located in a different cabinet but the
same carrier and same slot as the administered fiber endpoint. The administered
fiber endpoint can be viewed with the
list fiber-link
command. This test can only
detect if the fiber endpoint connected to the SNI is in a different carrier, slot
location than the administered fiber endpoint.
If the SNI is connected to the same type of fiber endpoint as the administered
fiber endpoint, but the location is the same as administered except for the
cabinet, all phone calls will not work correctly; some phone calls will not go
through and some phone calls will ring the wrong phone.
The
test led
command can be used in this case to check connectivity.
1. First, run the
test led port-network
command on each administered port
network and verify that the LEDs on the correct port network are lit.
2. If not, check that the fiber connections to the port network are consistent
with the administered fibers (
list fiber-link
) that does not light the LEDs as
expected.
3. Then run the test led switch-node command on each administered switch
node carrier and verify that the LEDs on the correct switch node carrier
are lit.
4. If not, check the connectivity to the switch node carrier that does not light
the LEDs as expected.