DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1032MEM-BD (32MB Memory Circuit Pack)
9
Table 9-407. TEST #903 RAM Checksum Test
Error
Code
Tes t
Result Description/ Recommendation
100 ABORT The requested test did not complete within the allowable time period.
1. Retry the command.
1022
1335
2500
ABORT Internal system error.
1. Retry the command.
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
This may be caused by a planned interchange initiated automatically during 24
hour scheduled testing.
1. Wait 3 minutes and retry the command.
1339 ABORT The test could not run on the standby Memory circuit pack in the standby SPE
carrier because the standby SPE is unavailable.
1. Refer to the section on "STBY-SPE (Standby SPE Maintenance)" procedures
for information on why a standby SPE may be unavailable and what repair
actions should be taken. The status spe screen should indicate that
handshake is down. This may be caused by a variety of reasons such as
the SPE-SELECT switches on the DUPINT circuit packs being set to the
position of the active SPE, a failure of the DUPINT circuit pack, or loss of
power on the standby SPE. The
SPE Selected field
on the status
spe-standby screen will display
spe a
or
spe b
if both SPE-SELECT
switches are in the a or b positions, respectively.
2000 ABORT Response to the test request was not received within the allowable time period.
If the system is equipped with the High Reliability or Critical Reliability
Configuration and if the Memory circuit pack is on the standby SPE, this abort
code may indicate that the standby SPE is not responding to the handshake
message. If this is the case, the standby SPE maintenance software may take
up to two minutes to indicate that handshake communication with the standby
SPE is down. The ABORT code will then change to 1339 (handshake
communication down).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2315 ABORT The test was not run, because this is an extra Memory circuit pack. No testing is
allowed for extra Memory circuit packs.
2334 ABORT The hardware mailbox on the standby Duplication Interface board is not ready
to receive messages.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
Continued on next page