A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-91display errors
8
For more information see ‘‘Common Input Parameters’’ at the beginning of this
chapter.
Input Form
This form specifies which errors display on the report. When all selections have
been made, press
ENTER. If no selections are made, or if the schedule option is
specified, all errors from the last day that are associated with active alarms
display (or print).
Error Type
The report can be restricted to specific error codes. This field defaults to
all errors.
Error List
The report can be restricted to errors from one of three lists described
below: active-alarms, errors, or cleared-errors. Default is active-alarms.
Interval
Specifies error records for the last month, hour, day, week, or all errors
(m, h, d, w, a). The default is all.
From
Specifies error records starting from the time specified by
mm/dd/hh/mm (month/day/hour/minute). If no “from” date is entered,
errors from the earliest record in the log are displayed.
To
Specifies all error records up to the time specified by mm/dd/hh/mm. If
no “to” date is entered, all errors up to the current date are displayed.
Equipment
Type
To limit the report to a specific group of components, enter the location
of a type of equipment in one of the following fields. If no entry is made,
errors for the entire system are displayed.
Cabinet: Enter the cabinet number (1-22).
Port Network Number: 1-22
Board Number: Enter the cabinet-carrier-slot address of the circuit
pack (for example, 11c04). If the cabinet number i omitted, it
defaults to 1.
Port: Enter the cabinet-carrier-slot-circuit address of the port (for
example, 11c0408). If the cabinet number is omitted, the system will
default to 1.
Category: errors for a particular equipment category. See the list of
alarm and error categories at the beginning of this chapter. The
HELP key displays a list of categories.
Extension: Enter the extension number of a port.
Trunk (group/member): Enter a trunk group number, or a trunk group
and member number separated by a slash (for example, 78 or 78/1).