DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-356BRI-SET, ASAI-ADJ, BRI-DAT
9
BRI Set Audits Test (#630)
This is a series of two tests which are classified as audits. The switch sends
messages to the BRI endpoint to perform the following tests:
Ringer Audit - This audit insures that both the switch and the endpoint
agree as to the current state of the endpoint’s ringer.
Lamps Audit - This audit insures that both the switch and the endpoint
agree as to the current state of the endpoint’s lamps.
Call Activity Audit - This audit insures that the state of calls is consistent
between the switch and the endpoint.
This test is not executed for ASAI or Lucent adjunct because adjuncts do not
employ ringers or lamps, or establish calls on the B-channels associated with the
BRI interface.
2000 FAIL No response is received from the endpoint or the adjunct. For BRI
endpoints:
1. Consult the endpoint documentation to determine if ISDN-BRI
Management and Maintenance Procedures are supported. If not
supported, use the change station extension command to change the
‘‘MIMs Supported?’’ field to ‘‘no.’’ Use the busyout station extension
and release station extension commands to busyout and release the
endpoint to resolve any endpoint alarms resulting from failure of this
test.
2. If the endpoint supports these procedures and the test continues to fail,
assume the endpoint is defective and replace it.
PASS The endpoint has successfully responded to the switch’s application
message.
Table 9-154. TEST #629 BRI Layer 3 Query — Continued
Error
Code
Te st
Result Description/ Recommendation
Continued on next page