DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1625SYSTEM (System)
9
Error Log Entries and Test to Clear Values
Notes:
a. Software requested a System Restart Level 3.
b. Software requested a System Restart Level 2.
c. Software requested a System Restart Level 1.
d. An error occurred during initialization.
e. Translation data was corrupted, so the system requested a Restart Level 3
to reload translation data from the Mass Storage System (MSS).
f. A reset system interchange or a scheduled SPE interchange failed. The
AUX Data indicates the cause of the failure. Consult the table in note p.
Use status spe to determine the current SPE status and follow the
Standby SPE Maintenance procedures to resolve the problems that are
preventing the SPE interchange.
Table 9-614. System Error Log Entries
Error Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
8 (a) 0 None
9 (b) Any None
10 (c) Any None
601 (d) Any None
602 (e) Any None
605 (f) (p) None
606 (g) Any None
607 (h) Any None
6001 (i) Any None
6002 (j) (o) None
6003 (k) (o) None
6101 (l) Any None
6102 (m) (o) None
6103 (n) (o) None