![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg91a.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1646TAPE
9
■ Tape external looparound test failed
■ Command failed with bad sense key
■ Tape could not be accessed
■ Flaw detected in tape medium
■ Unrecoverable hardware error on tape
■ Invalid parameter in SCSI command
■ Media removed or device reset
■ Tape is write protected
■ Tape reached end of medium
■ Block reassigned on tape
■ Block reassignment on tape failed
Also this test checks for two other conditions: the presence of grown defects on
the tape medium, and whether the tape has been accessed in excess of 90% of
the manufacturer’s suggested maximum.
Table 9-620. TEST #812 Tape Firmware Error Counters Read
and Clear Test
Error
Code
Tes t
Result Description/ Recommendation
1305 ABORT Could not read firmware error counters.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1306 ABORT Could not read configuration area for defect information.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1316 ABORT Could not get access to the Mass Storage System. Other application software
may be using it or background maintenance tests may be running.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, verify that the daily translation-save
operation is not in progress (issue the display system-parameters
maintenance command to display the time for scheduled maintenance
and the "y/n" option for saving translation daily).
1335 ABORT Could not run the test on the Standby SPE—Duplication not administered.
1. Refer to the documentation for STBY-SPE maintenance.
2. Administer standby present.
Continued on next page