![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg1a6.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-111display system-parameters maintenance
8
Modem Connection
On page 3 of the example forms shown below, there are 11 fields that are hidden
when the
Modem Connection?
field is set to
internal
. In this example the
Modem Connection
field is set to
external
, and these additional 11 fields are
visible.
The first 2 fields on page 3 help setup the data format for the serial data from the
switch to the modem.There are only two valid combinations for these 2 fields:
■ Data Bits = 8, Parity = None
■ Data Bits = 7, Parity = (odd, even, mark, or space)
The remaining fields are listed below:
Loss Plan
Use only when extra loss is required to maintain quality of
transmission on conference calls. Leave this field blank if no
extra loss is required. If extra loss is required, enter digits as
shown below.
No. Of Parties To
Be Conferenced Enter Digit
32
43
54
65
76
SPE Optional
Boards:
These fields indicate whether a Disk circuit pack is present in the
system, and which Packet Interface slots are administered. If a
Packet Interface circuit pack is physically present, the
corresponding Packet Interface field is set to y when the system
boots, and no change to that field is allowed. If the system is
equipped with duplicated SPEs, a Packet Interface field is set to y
when either SPE carrier contains a Packet Interface circuit pack in
the corresponding position. If a Packet Interface circuit pack is not
present, then the value for the Packet Interface field is read from
translation data stored on disk or tape. If the field is set to n, a
Packet Interface circuit pack may be administered by changing the
corresponding Packet Interface field to y.
Modem
Connection
Internal or external (internal)
Modem Name This field is 20 characters long and will permit alpha-numeric
characters to provide a unique qualifier for a given modem. ( )