DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Alarms, Errors, and Troubleshooting
5-27ATM Tips
5
Table 5-4 shows the pin assignments for the cable used to connect the TN574
DS1 CONV circuit pack to DS1 facilities.
ATM Tips
This section provides tips for DEFINITY ATM PNC when interfacing with the Cajun
Networks A500 ATM switch. Throughout this section, refer to Figure 5-6
.
Table 5-4. DS1 Interface Cable Connectors
Lead Desig.
50-Pin
Connector
Pin
15-Pin
Connector
Color Pin Color
Plug 04
Facility D Line In LID 38 W-BL 11 W-BL
Facility D Line In LID* 13 BL-W 03 BL-W
Facility D Line Out LOD 39 W-O 09 W-O
Facility D Line Out LOD* 14 O-W 01 O-W
Plug 03
Facility C Line In LIC 41 W-G 11 W-G
Facility C Line In LIC* 16 G-W 03 G-W
Facility C Line Out LOC 42 W-BR 09 W-BR
Facility C Line Out LOC* 17 BR-W 01 BR-W
Plug 02
Facility B Line In LIB 44 W-S 11 W-S
Facility B Line In LIB* 19 S-W 03 S-W
Facility B Line Out LOB 45 R-BL 09 R-BL
Facility B Line Out LOB* 20 BL-R 01 BL-R
Plug 01
Facility A Line In LIA 47 R-O 11 R-O
Facility A Line In LIA* 22 O-R 03 O-R
Facility A Line Out LOA 48 R-G 09 R-G
Facility A Line Out LOA* 23 G-R 01 G-R