A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1055MET-LINE (MET Line)
9
MET Line Ringer Update Test (#62)
In this update, a ‘‘ringer on’’ or a ‘‘ringer off’’ message is sent to the firmware to
start and stop the ringer on the set.
PASS Hybrid Line Station Audits passed.
1. Although this test will never actually return a FAIL result except for the
Internal system error described above, it is possible that it will enter Error
Types 257 or 513 into the Error Log. To determine if there are any problems
that don’t show up in the test result, look for these error types in the Error
Log.
2. If these errors appear in the Error Log, or if user complaints persist,
investigate by using other circuit pack tests, and by examining the station,
wiring, and connections.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to ensure
that there is a valid board inserted.
Table 9-418. TEST #61 MET Line Station Audits Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page