DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Management Terminal
3-26Logging On
3
■ Standby SPE Connection
With duplicated SPEs, there are two SYSAM connectors on each PPN
control carrier (A and B). Either carrier’s connectors may be used. Either
ACTIVE connector always access the active SPE regardless of which
carrier is active. Either STANDBY connector accesses the standby SPE
through the SPE-Down interface. This interface is available when the SPEs
are locked by the SPE-Select switches on a system with duplicated SPEs.
Otherwise the STANDBY connection is inactive. (On a simplex SPE, this
interface is accessed when the SPE is down through the ACTIVE
connector). Separate terminals may be connected to the two connectors,
or one terminal may be switched back and forth between connections.
The unused connectors should be capped.
The SPE-down interface can only be accessed by SYSAM-LCL or SYSAM-RMT
connections. This interface is described in
Initialization and Recovery
.
Serial Printer Connection
For serial printer operation, connect the printer to the connector on the back of
the 715 BCS terminal labeled P1(DCE). A null modem is not required. Set the
printer for 9600 baud, 7 data bits and 1 stop bit. These are the default settings for
the 715 BCS. If necessary, terminal settings for serial printer operations can be
changed from the Communication Options sub-menu of the Setup menu.
Parallel Printer Connection
For parallel printer operation, connect the printer to the connector labeled with
the printer icon. To enable parallel printer operation, use the following series of
keystrokes.
1. Cntl + F1 to access the Setup menu
2. F4 to select the User Preferences sub-menu
3. Down arrow to the Parallel Port field
4. F4 to enable the option
5. F1, F5, F1 to return to Setup, save selections, and exit
Logging On
To log in to the system:
1. Connect and power up the MT; the screen displays login:
2. Enter your login name, and press the
Return key. The screen displays
password:
3. Enter your password, and press the
Return key.