![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg751.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1189PE-BCHL (PRI Endpoint Port)
9
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the UDS1
interface circuit pack to assure that the port’s translation is correct. The port audit
operation verifies the consistency of the current state of port kept in the UDS1
interface circuit pack and in the switch software.
Table 9-471. TEST #7 Conference Circuit Test
Error
Code
Te st
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be in
use on a valid call. Use status pri-endpoint extension commands to determine
when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use status pri-endpoint
extension to determine when the port is available for testing.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1020 ABORT The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack. Even though wideband calls do not use the
conferencing feature on the NPE, this failure indicates problems with the
circuit pack hardware.
PASS The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated using other port tests and examining
terminal adapter or external wiring.
Continued on next page