DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-972ISDN-TRK (DS1 ISDN Trunk)
9
Figure 9-53. Outgoing ISDN-PRI Test Call
Synchronous Test Calls
You can initiate a synchronous outgoing test call by entering one of the following
commands:
test trunk
group#/member#
long [repeat
#
]
test board
UUCSS
long [repeat
#
]
test port
UUCSSpp
long [repeat
#
]
The above test sequences include a test-call for ISDN-PRI trunks. The duration of
the test call is 8.6 seconds for If unrestricted (B8ZS) B-channels and 9.4 seconds
for restricted (ZCS) B-channels. The test fails if the bit error rate retrieved from the
Maintenance/Test digital port is greater than 0. When this occurs, you will need to
perform further diagnostics, such as the
test isdn-testcall
command described
below.
Asynchronous Test Calls
You can start, query, and stop an outgoing test call by using the following
maintenance commands:
test isdn-testcall group#/member# [minutes #]
This command initiates an outgoing ISDN-PRI test call for a maximum of
120 minutes. Default times are as above. Only one trunk per port network
can be tested at one time.
DS1 Facility
ISDN Trunk
(B-Channel)
UDS1
TN464
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
M/T
TN771
G3r Switch originating test call
TDM Bus
Far-End Switch
with test call
terminating capability
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.