DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1612SYSAM (Circuit Pack)
9
1318
1335
2029
2033
2500
ABORT Internal system error
1. Retry the command.
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
This may be caused by a planned interchange initiated automatically during
24 hour scheduled testing.
1. Wait 3 minutes and retry the command.
1339 ABORT The test could not run on the standby SYSAM circuit pack in the standby SPE
carrier because the standby SPE is unavailable.
1. Refer to the STBY-SPE maintenance documentation for information on
why a standby SPE may be unavailable and what repair actions should
be taken. The screen for the status spe command should indicate that
handshake is down. This may be caused by a variety of reasons such as
the SPE-SELECT switches on the DUPINT circuit packs being set to the
position of the active SPE, a failure of the DUPINT circuit pack, or loss of
power on the standby SPE. The SPE selected field on the status spe
screen displays spe a or spe b if both SPE-SELECT switches are in the
a or b positions, respectively.
2000 ABORT Response to the test request was not received within the allowable time
period. If the system is a High or Critical Reliability configuration and if the
SYSAM circuit pack is on the standby SPE, this abort code may indicate that
the standby SPE is not responding to the handshake message. If this is the
case, the standby SPE maintenance software may take up to two minutes to
indicate that handshake communication with the standby SPE is down. The
ABORT code then changes to 1339 (standby SPE unavailable).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2318 ABORT The standby SYSAM was not responding within the allowable time period.
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2334 ABORT The hardware mailbox on the standby Duplication Interface board is not
ready to receive messages.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
Table 9-609. Test #913 Time-Of-Day Clock Test — Continued
Error
Code
Te st
Result Description/ Recommendation
Continued on next page