Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-381CARR-POW (Carrier Power Supply)
9
Error Log Entries and Test to Clear Values
!
WARNING:
The OLS Recycle Test (#126) is destructive. For more information, refer to
the description of this test.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
Battery & Battery Charger Query Test
, for
example, you may also clear errors generated from other tests in the testing
sequence.
Table 9-159. Carrier Port Power Supply Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1
1
1. Run the OLS Query Test (#127) first using the test environment UUr 2 command. Then, if a
carrier must be recycled to clear the CARR-POW alarm, use the recycle carrier UUC command
to run the OLS Recycle Test (#126). The OLS Recycle Test (#126) is not included in either the long
or short test sequences.
0 or 1 OLS Query Test (#127) MAJOR ON test environment
UU
r 2
recycle carrier
UUC