![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg26c.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-309status synchronization
8
The following display shows a typical result when
status switch-node
is entered.
status synchronization
This command lists the synchronization source for the system.
Mode
The mode is the current role of the switch node carrier. A mode of
"active" means the SN is providing normal circuit and control functions
for PNC. A mode of "standby" means the SN is ready to become active,
but is currently not active. If blanks are displayed it means that PNC is
not duplicated.
Major
Alarms
The number of major alarms logged against the switch node carrier that
is being displayed.
Minor
Alarms
The number of minor alarms logged against the switch node carrier that
is being displayed.
Warning
Alarms
The number of warning alarms logged against the switch node carrier
that is being displayed.
Active SNC
Location
The physical position of the active switch node Clock circuit pack, per
administration, represented as "UUcSS." "UU" represents the cabinet
number, "c" represents the carrier, and "SS" represents the slot position.
If an SNC is administered but not inserted, "no board" will be displayed.
Standby SNC
Location
The physical position of the standby switch node Clock circuit pack,
per administration, represented as "UUcSS." "UU" represents the
cabinet number, "c" represents the carrier, and "SS" represents the slot
position. Blanks will be displayed if there is no standby switch node
Clock for a given switch node. If an SNC is administered but not
inserted, "no board" will be displayed.
Action/ Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status synchronization
print
init
inads
craft
none none
status switch-node 1 page 1 of 1
switch node STATUS
Major Minor Warning Active SNC Standby SNC
Switch Node Location Mode Alarms Alarms Alarms Location Location
1 A-PNC 01E active 0 0 0 01E10 01E12
1 B-PNC 01D standby 0 1 2 01D10 01D12