9-740DUPINT (Duplication Interface Circuit Pack)
9
Active DUPINT Reset Test (#870)
This test is destructive
.
This test checks the HFAIL bit in the active Duplication Interface circuit pack and
attempts to reset the circuit pack if the HFAIL bit is set. The state-of-health of the
standby SPE must be
partially functional
for this test to run.
55 FAIL The attempt to turn off memory shadowing in this Duplication Interface circuit
pack could not be verified in the hardware status register.
1. Replace Duplication Interface components starting with the active
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of the DUP-CHL
section.
PASS The looped around test word within the shadowing bounds matched the
inversion of the written test word and the retrieved test word outside the
shadowing bounds did not match the inversion of the written test word. The
test words are looped within the active Duplication Interface circuit pack.
Table 9-286. Test #870 Active DUPINT Reset Test
Error
Code
Tes t
Result Description/ Recommendation
1419 ABORT A standby state-of-health of
functional
or
not refreshed
prevented the test
from running.
1. Manually lock the active SPE by moving the SPE-select switches located
on the front of the DUPINT circuit pack to positions where they are both
selecting the currently active SPE.
2. Rerun the test.
3. If the test passes, then unlock the active SPE by moving both SPE select
switches to the Auto position and rerun the test duplication-interface
long command.
4. If the test fails or aborts, replace the active DUPINT circuit pack. Use
procedures described in
Replacing Duplication Channel Components
in
the DUP-CHL section.
Continued on next page
Table 9-285. TEST #868 Memory Shadowing Bounds Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page