Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-354test mssnet
8
test mssnet
test mssnet C [short | long][repeat
|clear][schedule]
The
test mssnet
command runs a series of diagnostic tests on the MSSNET
circuit pack. Tests are run on both maintenance objects located on the MSSNET
circuit pack: host-adapter (H-ADAPTR) and switch control (SW-CTL).
Parameters
Output
The following display shows a typical result when
test mssnet 1a
is entered.
C
The cabinet is always 1 and need not be entered. The carrier,
a
or
b
, must be
specified in a duplicated SPE system.
clear
The clear option does not provide a useful function for this command. MSSNET
is used only as a command object to run tests of the MSSNET circuit pack.
Failures of circuits on the MSSNET board cause alarms against H-ADAPTR and
SW-CTL. Individual demand tests of those maintenance objects should be used
to clear associated alarms.
test mssnet 1a SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A H-ADAPTR 822 PASS
01A H-ADAPTR 823 PASS
01A H-ADAPTR 824 PASS
01A H-ADAPTR 825 PASS
01A SW-CTL 92 PASS
Command Successfully Completed