Crossroads Systems 20-Feb Portable Media Storage User Manual


 
A-14 Appendix A
Error Code and Qualifier Reference
Library Error Codes
Interpreting Error Code Qualifiers
One or more of the following qualifiers are frequently displayed with an
error code. Use the recovery methods to assist in determining
appropriate diagnostic tests and in isolating the error. This list may
change if the firmware is updated.
Table A-2 Error Code Qualifiers
Decimal
Error
Hex
Error
Description Recovery Method
0 00H Qualifier code is unknown. Check the error code.
1 01H Vertical control system detected
an over voltage.
Check the error code.
Clear the vertical path.
Clear the transport path.
2 02H Vertical control system detected
an over force.
Power the unit down.
Clear the vertical path.
Clear the transport path.
Power the unit back on.
3 03H Vertical control system detected
an error.
Power cycle.
Clear the vertical path.
Clear the transport path.
4 04H Vertical control system timed out. Power cycle.
7 07H Vertical control system detected
an unknown error.
Power cycle.
10 0AH Plunge control system detected an
over voltage.
Check the error code.
Clear the transport path.
11 0BH Plunge control system detected an
over force.
Power the unit down.
Clear the transport path.
Power the unit back on.