Crossroads Systems 20-Feb Portable Media Storage User Manual


 
Appendix A A-9
Error Code and Qualifier Reference
Library Error Codes
Error Code Reference Error Code Reference
Error Codes
78 4EH Not all drives in the
library are the
same type.
Check to ensure that you have the correct
type of drive.
80 50H Drive reports
hardware error.
Power cycle the library and re-try.
Replace the drive module if unsuccessful.
Removing and Replacing Drive Modules
on page 6-21.
81 51H Library failed
during
initialization.
Power cycle the library.
82 52H Incorrect external
SCSI connection.
Library connected
to wrong type of
SCSI bus.
Check the cable configuration (Connecting
and Powering on the Library (for Models 2/20,
4/40, and 6/60) on page 2-28).
100 64H Library controller
unable to
communicate with
drive module.
Power cycle the library.
101 65H Drive module
unable to
communicate with
drive.
Power cycle the library.
102 66H Drive command
timeout on drive
module controller.
Command timeout on 8051.
103 67H A drive module
controller has
failed.
Power cycle the library and re-try. Replace the
drive module if unsuccessful (Removing and
Replacing Drive Modules on page 6-21).
104 68H Failed drive module
initialization.
Power cycle the library.
Table A-1 Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description Recovery Method