Chapter 5 5-23
Errors and Troubleshooting
Understanding Error States
Errors and Troubleshooting
Errors & Troubleshooting
Front panel failed Front panel display failed
power-up test.
Power cycle the library.
See page 5-39.
Slave card failed Library slave controller card
failed power-up test.
NOTE: Slave controller cards
are required in all but the lowest
level of the library.
Ensure the slave card is seated
properly.
Ensure that the fans on the
same level of the library are
moving, and that the slave card
LED is lit. If not, ensure that
the power cables are properly
seated.
Power cycle the library.
Fibre Channel
card failed
Fibre Channel card failed
power-up test. (Usually due to
problems on the SCSI bus, such
as an LVDS drive or terminator
on an HVDS bus, etc.)
Verify that proper SCSI
terminators and/or tape drives
are attached to the Fibre
Channel card, and then reboot
the library.
Power cycle the library.
Power supply
fault
Library detected one or more
redundant power supplies in a
failed condition.
Determine which power supply
failed. See page 5-14 for LED
status information.
Table 5-13 Partial Availability Conditions
Library Status Cause Solution