ANR8279E (AS/400)
Command: exit type EXIT program name is invalid.
Explanation: The syntax of the specified program name is invalid.
System Action: The server does not process the command.
User Response: Reissue the command and specify a different program name.
ANR8280W (AIX)
Error loading dsmtli.drv for IPX/SPX or NetBIOS communications methods.
Explanation: The server cannot load file dsmtli.drv to initialize a communications
driver.
System Action: Server operation continues. The communications method that was
initializing is inoperative. This may be either NetBIOS, IPX/SPX or both, depending
upon the contents of the server options file dsmserv.opt.
User Response: NetWare for AIX, IBM NetBIOS and IPX Support, or AIX
Connections must be installed on your system to use IPX/SPX communications.
IBM NetBIOS and IPX Support or AIX Connections must be installed on your
system to use NetBIOS communications. File libtli.a is accessed as part of the load
process through module dsmtli.drv. This file should be in the same directory as the
dsmserv executable or it must be in a directory that is pointed to by the
DSMSERV_DIR environment variable.
ANR8280E (AS/400)
Command: One or more libraries are still defined to use the exit type EXIT.
Explanation: The designated exit cannot be deleted because there are still libraries
defined to use the exit.
System Action: The server does not process the command.
User Response: Delete all the libraries that use the exit and reissue the command.
ANR8280I (Windows NT)
HTTP driver ready for connection with clients on port port number.
Explanation: The server can now accept sessions with clients using the HTTP
protocol on the indicated port number.
System Action: Server operation continues.
User Response: None.