Tivoli Audio Version 3 Release 7 Portable Media Storage User Manual


  Open as PDF
of 1473
 
ANR3508W Generation of backup set for node name as set name failed - no filespaces to
process.
Explanation: The named object for the specified node was not created. No
filespaces were available to process.
System Action: Server operation continues.
User Response: Reissue the command against a node that has filespaces associated
with it. If no filespaces exist for a given node, than there is no file data to write to
the backupset.
ANR3509E Command: Error encountered in accessing data storage - device class device
class name is not defined.
Explanation: During command command processing, an error occurred because
the specified device class is not defined.
System Action: The command command is ended and server operation continues.
User Response: Make sure the specified device class is defined.
ANR3510E Command: Error encountered in accessing data storage - disk volume specified.
Explanation: During command command processing, an error occurred because a
specified volume is a disk volume rather than a tape volume.
System Action: The command command is ended and server operation continues.
User Response: Make sure that all volumes specified for the command command
are tape volumes.
ANR3511E Command: Error encountered in accessing data storage - invalid volume name
specified.
Explanation: The server encounters an error in accessing data storage while
processing command command. The error occurred because an attempt has been
made to access a volume with an invalid name.
System Action: The command command operation is ended and server operation
continues.
User Response: Issue the command with a valid volume name.
ANR3512E Command: Error encountered in accessing data storage - insufficient number of
mount points available for removable media.
Explanation: During command command processing, the server cannot allocate
sufficient mount points.
480
Version 3 Release 7