message on an AS/400 message queue. Locate the AS/400 message and provide an
appropriate reply. The job should be located in the QSYSWRK subsystem.
System Action: The server waits for a reply to the AS/400 message.
User Response: Locate the AS/400 message and provide an appropriate reply.
ANR8707W (AS/400)
Access state for volume volume name in library library name has been set to
unavailable.
Explanation: The specified volume encountered an error during mount processing
that makes it unusable. The access state of the volume in the library volume
inventory is changed to unavailable so that the volume is not selected for future
mounts. One of the following may be the cause of the error. The volume may
already be queued for use in the media library device. The volume may be mounted
in another tape resource that is not available to the media library device. The
volume was marked not available, or in error by the library device manager. The
volume identifier may be a duplicate. The volume may have been manually ejected
from the library device.
System Action: The server sets the volume access state to unavailable. If the
server operation requires a scratch volume, processing continues with another
scratch volume. If the server operation required the given volume, the operation is
terminated.
User Response: Check previously issued ADSM messages for additional
information regarding the error. Check the spooled files of the AS/400 user that
started the ADSM server for messages that describe the problem with the given
volume. The AS/400 Display Tape Cartridge (DSPTAPCTG) command can be used
to display the attributes of a tape volume. Once the problem is corrected, update the
access state of the volume to available by using the UPDATE LIBVOL command.
An audit of the ADSM library will also result in a re-evaluation of the condition of
the volume. If the volume is usable, it’s access state will be changed to available.
An audit of the ADSM library occurs automatically during server initialization or an
audit of the library can be started with the AUDIT LIBRARY command.
ANR8708W (AS/400)
The characteristics of device device name have changed: current device type
new device type, original device type old device type.
Explanation: The current characteristics of the designated device do not match the
characteristics of the device when it was originally defined to the server. Either the
device type has changed or the supported formats have changed. One of the
following may be the cause of the change. The original device may have been
replaced with a new device. The AS/400 configuration has changed resulting in
different names being assigned to existing devices. The original device may have
980