User Response: None.
ANR4254E Audit command: Data storage high-water marks do not match the identifiers in
use.
Explanation: A database audit process finds that the information used to track data
storage identifiers is incorrect.
System Action: Audit processing continues.
User Response: Reissue the audit command and specify FIX=YES so that the
error can be corrected.
ANR4255E Audit command: Data storage high-water marks do not match the identifiers in
use - they will be corrected.
Explanation: A database audit process finds that the information used to track data
storage identifiers is incorrect. Because FIX=YES has been specified for the audit
command, the error will be corrected.
System Action: Audit processing continues.
User Response: None.
ANR4256I Audit command: Auditing data storage definitions for disk volumes.
Explanation: This message is displayed during a database audit and indicates that
the database information relating to data storage disk volumes is being examined by
the database audit process.
System Action: Audit processing continues.
User Response: None.
ANR4257E Audit command: A correctable data-integrity error was detected on volume
volume name.
Explanation: A database audit process finds a data-integrity error for a file stored
on the specified volume. This error is correctable.
System Action: Audit processing continues.
User Response: Reissue the audit command and specify FIX=YES so that the
error can be corrected.