ANR8245W (AIX)
Unable to create APPC thread.
Explanation: The server cannot initialize due to the inability to create a new
thread of execution.
System Action: Server operation continues, but APPC communications are not
established.
User Response: The most likely cause is a lack of memory. The system process
table may also be full. Ensure that sufficient paging space is available for AIX. You
may also use SMIT to determine if the number of applications is causing a memory
shortage. You may also decrease the maximum number of sessions that the server
can accept with the MAXSESSIONS option in the server options file.
ANR8245W (Windows NT)
IPX/SPX driver unable to initialize due to error in BINDing to Port port,
reason code reason code.
Explanation: While initializing IPX/SPX communications, the server has failed to
connect to a master socket on which to listen for clients. The reason code is the
return code from the IPX/SPX bind API.
System Action: Server operation continues, but the server cannot accept sessions
from clients using the IPX/SPX protocol.
User Response: Ensure that no other application is using the port number
specified in the server options file with the PORT option.
ANR8246W (AIX)
Error sending data on connection descriptor connection descriptor. Terminating
session session number.
Explanation: The server experiences an error return code from APPC while
sending data over the indicated server session number. This may be a normal event
if either side of the connection is abruptly ended.
System Action: The session is ended. Server operation continues.
User Response: If the session is ended as a result of intentionally stopping either
the client or server, no response is required. Otherwise, ensure that the client and
server can communicate over an APPC connection.
842